Difference between revisions of "7501T8"

From Sensoray Technical Wiki
Jump to: navigation, search
(Using with model 826)
(Using with model 826)
Line 111: Line 111:
 
|}
 
|}
  
The relay rack can be connected to header J3 or J2 on the 826 board. The GPIO associated with each SSR depends on whether the relay rack is connected to J3 or J2, as shown in the GPIO mapping table. For example, if the relay rack is connected to J2 on the 826 board then SSR2 will be connected to GPIO26.
+
The relay rack can be connected to header J3 or J2 on the 826 board. The GPIO mapping table (shown to the right) shows the GPIO associated with each SSR. The mapping depends on whether the relay rack is connected to J3 or J2. For example, if the relay rack is connected to J2 then SSR2 will be routed to GPIO26.
  
 
You must supply 5 VDC power to the relay rack. This can be done in either of the following ways:
 
You must supply 5 VDC power to the relay rack. This can be done in either of the following ways:
 
* Connect an external 5 VDC power source to the relay rack's +5V and GND terminals.
 
* Connect an external 5 VDC power source to the relay rack's +5V and GND terminals.
 
* On the bottom of the relay rack, attach a wire (via solder) from the +5V terminal to J1 pin 49.
 
* On the bottom of the relay rack, attach a wire (via solder) from the +5V terminal to J1 pin 49.

Revision as of 15:14, 12 July 2018

Model 7501T8 is a solid-state relay (SSR) rack that accommodates up to eight G4 type SSR modules. It has a 50-pin header which is compatible with several Sensoray GPIO products, including models 826 and 2410.

Pinout

SSR Header
Pin
Terminal
Block Pins
Model 826
J3 GPIO
Model 826
J4 GPIO
Model 2410
GPIO
0 47 1-2 0 24 17
1 45 3-4 1 25 19
2 43 5-6 2 26 21
3 41 7-8 3 27 23
4 39 9-10 4 28 9
5 37 11-12 5 29 11
6 35 13-14 6 30 13
7 33 15-16 7 31 15

Using with model 826

GPIO mapping for model 826
SSR 826 GPIO
J3 J2
0 0 24
1 1 25
2 2 26
3 3 27
4 4 28
5 5 29
6 6 30
7 7 31

The relay rack can be connected to header J3 or J2 on the 826 board. The GPIO mapping table (shown to the right) shows the GPIO associated with each SSR. The mapping depends on whether the relay rack is connected to J3 or J2. For example, if the relay rack is connected to J2 then SSR2 will be routed to GPIO26.

You must supply 5 VDC power to the relay rack. This can be done in either of the following ways:

  • Connect an external 5 VDC power source to the relay rack's +5V and GND terminals.
  • On the bottom of the relay rack, attach a wire (via solder) from the +5V terminal to J1 pin 49.