Difference between revisions of "7501T8"

From Sensoray Technical Wiki
Jump to: navigation, search
(Using with model 826)
(Using with model 826)
Line 68: Line 68:
 
|}
 
|}
  
==Using with model 826==
+
==Using with Sensoray 826==
  
 
{| class="wikitable" style="float:right; margin-left:20px;"
 
{| class="wikitable" style="float:right; margin-left:20px;"

Revision as of 07:00, 13 July 2018

Model 7501T8 is a solid-state relay (SSR) rack that accommodates up to eight G4 type SSR modules. It has a 50-pin header which is compatible with several Sensoray GPIO products, including models 826 and 2410.

Pinout

SSR Header
Pin
Terminal
Block Pins
Model 826
J3 GPIO
Model 826
J4 GPIO
Model 2410
GPIO
0 47 1-2 0 24 17
1 45 3-4 1 25 19
2 43 5-6 2 26 21
3 41 7-8 3 27 23
4 39 9-10 4 28 9
5 37 11-12 5 29 11
6 35 13-14 6 30 13
7 33 15-16 7 31 15

Using with Sensoray 826

GPIO mapping for model 826
SSR 826 GPIO
J3 J2
0 0 24
1 1 25
2 2 26
3 3 27
4 4 28
5 5 29
6 6 30
7 7 31

You must supply 5 VDC power to the relay rack. This can be done in either of the following ways:

  • Connect an external 5 VDC power source to the relay rack's +5V and GND terminals. The 5 VDC power source must share a common ground with the computer power supply.
  • On the bottom of the relay rack, attach a wire (via solder) from the +5V terminal to J1 pin 49. This will use +5 V from the 826 board to power the relay rack.

The relay rack can be connected to header J2 or J3 on the 826 board. The GPIO mapping table (shown to the right) shows the GPIO associated with each SSR, which depends on whether the relay rack is connected to J2 or J3. For example, if the relay rack is connected to J2 then SSR2 will be associated with GPIO26.

An output SSR is controlled by writing to its associated GPIO, whereas an input SSR is monitored by reading from the GPIO. Model 826 has active-low GPIOs and the relay rack is designed for active-low signaling. Consequently, you must write '1' to turn on an output SSR and write '0' to turn it off. Similarly, when reading an input SSR, '1' indicates the relay is on and '0' indicates off.

Personal tools